1 Formula a gold plating solution
#1 Formula a gold plating solution
- 2 real gold shares, or about 0.75 grams.
- Nitric acid (nitrate) 10 cc
- Hydrochloric acid (hydrochloric acid) 20 cc
- Sodium cyanide 20 g (or 1 cube).
- 1 liter of water.
- Plating temperature 60 degrees, or normal
- 3-12 V voltage.
- Density of current.
- The lure real gold bar.
- Colorless liquid coating characteristics (use the long yellow).
Note If you want a gold plating solution concentration than this, add the use of gold as much as 1-2 grams.
Gold plating solution is concentrated. Surface coating is thick, peel slowly
The amount of nitrate and hydrochloric acid, not the exact Hai, but only the ratio of 1:2 and total amount of both acids are used to flood gold.

Categories